Programme unit
Input and outputs on I/O cards 1 and 2
Cardswitch I/O-card1A11 I/O-card2A12
Serial interface and voltage supply
X1: 1-3 Serialinterfacetocard2 -
4 16V+supplytocard2 -
5 0V–supplytocard2 -
X2: 1 0V–supplytoCPU 12V-fromcard1
2 16 V+ supply to CPU 12 V+ supply from card 1
3-5 SerialinterfacetoCPU Serialinterfacetocard1
X3: 1 16V+supplyfromT10 -
2 0V-supplyfromT10 -
X6: 1 230 V supply from emergency stop, phase 230 V direct supply, phase
2 230 V supply from emergency stop, neutral 230 V direct supply, neutral
X10:1 Interlock signal to motor controller, phase Supply to relays from I/O 1, phase
2 Interlock signal to motor controller, neutral Supply to relays from I/O 1, neutral
X11:1 SupplytorelaysfromI/O2,phase -
2 SupplytorelaysfromI/O2,neutral -
X12:1 ToX13:supplytorelays11-14,phase ToX13:supplytorelays11-14,phase
2 ToX13:supplytorelays11-14,neutral ToX13:supplytorelays11-14,neutral
X13:1 Supplytorelays11-14,neutral Supplytorelays11-14,neutral
2 Supplytorelays11-14,phase Supplytorelays11-14,phase