42
Troubleshooting
WATER IN DRUM
The water level is higher than EMPTY at
programme start.
First verify whether:
• thesameerrorappearsagainfollowingreset-
ting of the error code
• thedrainisblockedbyufforfoam
• thelevelhoseandairboxareblocked(blow
into the level hose)
• Formachineswithadrainpump,verifycor-
rection operation.
Pay attention to temperature extremes in the
surrounding which may affect the level system,
generating this error code.
1. Verify whether there is any water in the drum.
Water in drum No water in drum
2. Enter the service program and record the
actual level value. Disconnect the level hose
from the programme unit card A1.
Level value does Level value falls
not change
Thelevelhoseisprobablyblockedbyuff
or due to incorrect installation. Verify and
clean, or replace the hose.
Level detector on programme unit card A1 is
defective.
Verify the operation of the drain valve using the service
programme. Remedy or replace the defective drain valve if
necessary.
21
21
3972
Level hose connection
20
Level indication
20
SERVICE PROGRAM
LEVEL 2
TEMP 22°C
SPEED 0
DRAIN CLOSED YES
EMERGENCY STOP DOOR LOCKED
TEMPORARY PAUSE DOOR CLOSED
OIL
REMOTE START IMBALANCE
SERVICE
PHASE CHECK