Programme unit
DRAIN OPEN DELAY 0:13
START EXTRACT TIME 00:30
ROLLOUT TIME 00:01
PAY PER WASH ALARM 0
LOCK TEST DELAY 0:10
DRAIN TIME WHEN OVERFILL 0:05
OIL LUBRICATION HOURS 100
PULSE TIME OIL LUBR. SEC 0:01
AMOUNTOFI/OMODULES(1-3) 3
DELAY CLEAR DOOR TEXT 04:00
MAX DRAIN TIME 4:00
TIMEOUT DURING PAUSE 1:00
Time drain to open after over-filling
Here you determine how long the drain valve
shouldopenforifthemachinehasover-lled,
provided you ensure that the parameter (response)
storedforthefunctionERROROVER-FILLEDis
N (No) (see below). The drain valve will open for
the time programmed and the level will then be
checked. If the level is still too high, the drain valve
will open again, and so on.
Over-llingcanoccurifawatervalveisfaulty,orif
youhaveover-lledthemachinemanually.
Also under ”SETTINGS 2” there are two functions
whichinuencethewaythemachinereactsto
over-lling:
ERROROVER-FILLED
If you answer Y (Yes): if the drum becomes
over-lled,themachinewillstopandtheerror
message”MACHINEOVER-FILLED”willbe
displayed.
If you answer N (No): the drain valve will open
as described above.
LEVELOVERFILL(i.e.DRUMOVER-FILLED)
Here you specify the level at which the drum is
consideredtobe”over-lled”.
Use the numeric keys to
enter the value.
If you make a mistake while
entering digits:
Press ERASE.
When you have finished:
Press .