Input De nitions
SC = Slack Cable Switch
LPS = Low Pressure Switch
GATE = Gate Switch
ESTP = Emergency Stop Switch
DC = Door Closed Circuit
DL = Door Locked Circuit
DZ = Door Zone Sensor
LD = Level Down Sensor
LU = Level Up Sensor
TF = (CR1) Limit Switch Relay
UP = Up Contactor Input
OVLD = Motor Overload
PF = Power Failure Relay
1-6 F = Floor Call Push Buttons
EZ 1-6 = EZ Magnet Sensors
SW1 = Autogate Programming Switch
Run = Run Contactor Input
SP = Safety Pan Relay
RS = Reset Switch
Output De nitions
RUN = Run Contactor Output
UP = Up Contactor Output
HSV = High Speed Valve Relay
DV = Down Valve Relay
LR = Cab Light Automatic Timer Relay
SV = Up Low Speed Valve Relay
EMI 1-6 = EMI Outputs
1-6 A = Floor Acknowledgement Lights in
the COP
AG1 = Autogate 1
AG2 = Autogate 2
AG3 = Autogate 3
DF = Door Fault
Input (I) 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7
IndicaƟ on
Gate Estop DC DL LPS PS TF OVLD
Output (Q)
0.0 0.1 0.2 0.3 0.4 0.5
IndicaƟ on
Run/In Use
Up HSV Down SV LR
Input (I)
8.0
8.1
8.2
8.3
8.4
8.5
8.6
8.7
9.0
9.1
9.2
9.3
9.4
9.5
9.6
9.7
10.0
10.1
10.2
10.3
10.4
10.5
10.6
Indication
SC
UP
RUN
PF
DZ
LU
LD
EZ1
EZ2
EZ3
EZ4
EZ5
EZ6
1F
2F
3F
4F
5F
6F
SP
RS
SW1
Outputs
(Q)
8.0
8.1
8.2
8.3
8.4
8.5
8.6
8.7
9.0
9.1
9.2
9.3
9.4
9.5
9.6
9.7
10.0
10.1
10.2
10.3
10.4
10.5
10.6
10.7
Indication
EMI1
EMI2
EMI3
EMI4
EMI5
EMI6
DF
1A
2A
3A
4A
5A
6A
AG1
AG2
AG3
GMV/OLS
MICROPROCESSOR
INPUTS & OUTPUTS
SERIES : 114 ,116
Note: Highlighted
Inputs MUST be ON
when the elevator
is stationary and in
automatic mode!
Page 55