138
USER MANUAL WebdynSunPM
Version 2.05
préliminaire
The reported values for IO and MODBUS alarms are raw and must be linked to the index
configuration in the device definition file. The IS must interpret the data using the raw data
file and the definition file to be able to apply the defined factors A and B and the unit for each
input or index. (see section 3.1.2.2.2: Definition file content”)
Example of a MODBUS alarm file:
21/02/12-07:00:19
MODBUS
MODBUS_DELTA_M88H-COM1.20-Sunspec.csv
OndA
48
0.000000
21/02/12-07:00:49
MODBUS
MODBUS_DELTA_M88H-COM1.20-Sunspec.csv
OndA
48
3.000000
4.1.5 “CMD” commands
(Future upgrade)
4.1.6 “SCRIPTS”
The “SCRIPT” directory on the FTP server is used to supply or retrieve Lua scripts to and from
the concentrator.
The script file format is below:
<comment>_.lua
Where:
<comment>: free user field
Examples:
ControlPower.lua
For more details on script use, see the “WebdynSunPM LUA User Guide.pdf” document
available at:
https://www.webdyn.com/support/webdynsunpm/
4.1.7 “BIN” update
The “BIN” directory on the FTP server is used to store the firmware used to update the
concentrator.
The update file format is below:
<uid>_wgapp_x.x.x.xxxxx.spm
Where:
<uid>: Concentrator identifier
x.x.x.xxxxx: is the firmware version number