1
WEILER E1650 REMIXING TRANSFER VEHICLE
5-42
Maintenance
5
Maintenance Procedures
Spray Down Filters - Check / Clean
Standard Tank
The spray down fluid pump and filter are located on rear of main frame, forward of discharge
conveyor.
1. Lower discharge conveyor.
2. Place a container under filter/water trap (1).
NOTICE: Do not allow contaminants to enter system.
Thoroughly clean area around filter before disconnecting.
3. Remove filter/water trap (1), clean filter/water trap,
and install.
To clean, unscrew filter base and pull screen out to
check for blockage. Clean strainer if needed and re-
assemble.
4. Replace components if damaged.
60 Gallon Tank (Optional)
1. Place a container under filter (1).
NOTICE: Do not allow contaminants to enter system.
Thoroughly clean area around filter before disconnecting.
2. Unscrew filter base and pull screen out to check for
blockage. Clean strainer if needed and re-assemble.
3. Replace components if damaged.