9 Servicing / Cleaning
Training manual Convotherm 4 122
Adjusting the door catch on table-top units:
1.
Open the appliance door.
2.
Place the adjustment gauge for table-top units in the position
shown in the illustration.
Check the gap between the lower fastener and the adjustment
gauge.
If the gap is > 1mm or the adjustment gauge does not fit behind
the catch fastener, the door catch must be readjusted.
3.
To do this, undo the fixing screw for the fastener
until the catch fastener can be adjusted in defined increments
set by the serrated edge.
4.
Adjust the catch fastener until the bottom fastener rests fully
against the adjustment gauge for table-top units.
5.
Re-tighten the fixing screw.