9 Servicing / Cleaning
Training manual Convotherm 4 128
Adjusting the door catch on floor-standing units: Height
1.
Open the appliance door.
2.
Place the adjustment gauge for floor-standing units in the posi-
tion shown in the illustration.
Check the gap between the fastener and the adjustment gauge.
If the gap is > 1mm or the adjustment gauge does not fit behind
the catch fastener, the door catch must be readjusted.
3.
To do this, undo the fixing screw for the fastener
until the catch fastener can be adjusted in defined increments
set by the serrated edge.
4.
Adjust the catch fastener until the fastener rests fully against
the adjustment gauge for floor-standing units.
5.
Re-tighten the fixing screw.
Adjusting the door catch on floor-standing units: vertical position
1.
Open the appliance door.
2.
Place the adjustment gauge for floor-standing units in the posi-
tion shown in the illustration.