5-2
Refer to page 4-6 for the procedure for ac-
cessing the inlet hot water valve.
To check the inlet hot water valve solenoids
at the component terminals, perform the fol-
lowing steps.
1. Unplug washer or disconnect power.
2. Disconnect the hot water solenoid con-
nector from the inlet hot water valve ter-
minals.
3. Set the ohmmeter to the R X 100 scale.
4. Touch the ohmmeter test leads to the hot
water connector terminals. The meter
should indicate between 825 and 1115
Ω.
INLET HOT WATER VALVE
SOLENOID
To check the inlet hot water valve solenoid at
the CCU, perform the following steps.
1. Unplug washer or disconnect power.
2. Disconnect the inlet hot water valve so-
lenoid connector VHF3 (see page 4-5)
from the CCU.
3. Set the ohmmeter to the R X 100 scale.
4. Touch the ohmmeter test leads to the fol-
lowing connector pins. The meter should
indicatebetween825and1115Ω.
Pins 1 & 2 (hot)•
1. DP2 Drain Pump
2. VPW3 & VW3 Cold / Bleach Valve
3. VHF3 Hot Valve
4. M7 Universal Motor