6-8
DIAGNOSTIC TEST
The two test modes contain three modes of
operation.
Test modes:
Universal test mode, with additional user •
interface test at the beginning.
Quick test mode•
Operation modes:
User interface test•
Automated test•
Loads tests to assist in diagnosing •
potentially non-electrical issue.
Starting Universal Test Mode
1. Close the door
2. Rotate the knob and select the CLEAN
WASHER cycle.
3. Press “CANCEL/DRAIN” button for 2
times, and then press “START” button for
2 times within 5 seconds.
4. Upon release, and after door locked, all
console LED lights will turn ON except
option LED.
5. Press the option buttons, one at a time, to
check the User Interface.
6. Following steps are automatically driven,
or they can be manually advanced by
pressing the Cancel/Drain button 2 time.
See table on page 6-9.