3.3.2 Defective Exhaust Valve Control Unit
The exhaust valve control unit must be shut off as an immediate procedure if the
piston or slide rod in the exhaust valve control unit is seized.
See 05201 Emergency operation with exhaust valve closed, paragraph 2.
Note: With one or more exhaust valve control unit(s) cut out, you can operate
the engine only at decreased load.
1) Replace the defective exhaust valve control unit as soon as possible (see
05201 Start the exhaust valve control unit, paragraph 3.2 and the Maintenance
Manual 56121).
3.3.3 Hydraulic Pipe to Exhaust Valve
1) If a hydraulic pipe to the exhaust valve is defective, cut out the injection of the
related cylinder. See 05101 Cut out the injection, paragraph 1.
2) Replace the defective exhaust valve control unit as soon as possible (see
05201 Replace the Defective VCU or Hydraulic Pipe and the Maintenance
Manual 84601).