Operation08501/A1
Winterthur Gas & Diesel Ltd.
16/ 39
Failure Text
WECS CAN S1-bus fail. (ID 1.2)
FCM20 No. LED Failure ID Display
Indication #01 to #09 S1 112 1.2
Cause CAN system bus #1 monitoring / CAN failure (failure signal is released after 3 seconds).
Procedure On the related FCM20 (plug X22, terminals 49/50), make sure that the cable connections
have no damage and are connected correctly.
Make sure that the S1-bus with 120 ohm resistors on first and last FCM20 (plug X22) is con-
nected correctly (refer to electrical drawings).
On the related FCM20, repair the cable connection / cables.
If the failure shows on one module only, replace the related FCM20.
Failure Text WECS CAN S2-bus fail. (ID 1.3)
FCM20 No. LED Failure ID Display
Indication #01 to #09 S2 113 1.3
Cause CAN system bus #2 monitoring / CAN failure (failure signal is released after 3 seconds).
Procedure On the related FCM20 (plug X23, terminals 57/58), make sure that the cable connections
have no damage and are connected correctly.
Make sure that the S2-bus with 120 ohm resistors on first and last FCM20 plug X23 is con-
nected correctly (refer to electrical drawings).
On the related FCM20, repair the cable connection / cables.
If the failure shows on one module only, replace the related FCM20.
Failure Text ME start pilot valve #nn loop fail. (ID 1.4)
FCM20 No. LED Failure ID Display
Indication #01 to #09 Start Vlv 114 1.4
Cause Broken connection or short circuit between FCM20 and start pilot solenoid valve
Procedure At the cylinder cover, make sure that the plug in the terminal box E95.41 to E95.49 has no
damage and is correctly connected.
Make sure that the cables between the related solenoid valve and the FCM20 (plug X15,
terminals 33/34) have no damage and are connected correctly.
Repair the cables and connections between the related solenoid valve and the FCM20 (plug
X15).
2014
Failures and Defects of WECS Components

Table of Contents