EasyManuals Logo

WinGD W-X82 User Manual

WinGD W-X82
548 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #227 background imageLoading...
Page #227 background image
Operation
08501/A1
Winterthur Gas & Diesel Ltd.
17/ 39
Failure Text
WECS cylinder lubrication passive failure. (ID 2.5)
FCM20 No. LED Failure ID Display
Indication #03 and #04 None 125 2.5
Cause Disconnected power supply #1 or #2.
Procedure In E85, E90 and E41.xx, make sure that the cables have no damage and are connected
correctly.
In E85, make sure that the all circuit breakers are set to on.
Repair the cables and connections in E85, E90 (terminals 40/41) and E41.xx (plug X2,
terminals 21/22).
In the FCM20 (plug X22, terminals 55/56) of the last and last but one cylinders, make sure
that the cables and connections have no damage and are connected correctly.
Do a check of the related ALM-20 CANM bus indications (LED CAN 1 or CAN 2).
If the bus indications show a failure, repair the cables of the last and last but one FCM20 (plug
X22, terminals 55/56).
Repair the cables in the related CANM bus. Make sure that the related ALM20 operates.
If after all ALM20 are started and the related ALM20 did not start, make sure that the cable
address on the plug X1 of the related ALM-20 is connected correctly.
Do a check of the ALM-20 (plug X1, terminals 16/17) and the related resistors (see 7218-1
Resistor in plug X1, paragraph 5.2).
Repair the cables and connections in the related ALM20.
If necessary, replace the defective ALM-20.
Failure Text ME waste heat recovery valve #1 not closed (ID 3.2.)
FCM20 No. LED Failure ID Display
Indication #01 None 232 3.2.
Cause Waste heat recovery valve #1 (main valve) is not closed. A command to close the main valve
was sent to the valve, but the sensor responses that the valve is in the open position.
Procedure Do a check of the position switch ZS5372C.
Make sure that the cables between the FCM-20 #01 and position switch ZS5372C have no
damage and are connected correctly.
If necessary, repair or replace the damaged cables.
If necessary, replace the position switch ZS5372C.
Failure Text ME waste heat recovery valve #1 not open (ID 3.3.)
FCM20 No. LED Failure ID Display
Indication #05 None 233 3.3.
Cause Waste heat recovery valve #1 (main valve) is not open. A command to open the main valve
was sent to the valve, but the sensor responses that the valve is in the close position.
Procedure Do a check of the position valve ZV7076C.
Make sure that the cables between the FCM-20 #05 and position valve ZV7076C have no
damage and are connected correctly.
If necessary, repair or replace the damaged cables.
If necessary, replace the position valve ZV7076C.
2014
Failures and Defects of WECS Components

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WinGD W-X82 and is the answer not in the manual?

WinGD W-X82 Specifications

General IconGeneral
BrandWinGD
ModelW-X82
CategoryEngine
LanguageEnglish

Related product manuals