Operation40024/A1
Winterthur Gas & Diesel Ltd.
2/ 2
3.4 Starting Air Control Valves
1) In the remote control, set to off one of the starting air control valves activated by
FCM20 of cylinder 1 or 2 (user parameter, function Start Valves Checking).
2) Do an an engine start with starting air (AIR RUN) only, or slow turning.
3) Do the test procedure again with the other starting air control valve.
Note: After each start, the WECS9520 automatically activates the two starting
air control valves.
4. Recommended Procedure to Replace FCM-20
Note: If possible, do this procedure when the engine has stopped.
If the engine must stay in operation and the FCM20 on cylinder No.3 or cylinder
No.4 must be replaced make sure that:
D If you replace the FCM20 on cylinder No.3, the Remote Control System (RCS),
or the Local Manual Control panel has control of the engine.
D If you replace the FCM20 on cylinder No.4, the RCS, or the ECR Manual
Control panel has control of the engine.
This will prevent an unwanted short engine stop / start.
Replace the FCM20 as follows:
1) Disconnect the power supply to the control box E90.
2) In the control box E90, disconnect the power supply to the FCM20 on the
related cylinder.
3) Remove the on line spare FCM20 from the control box E90.
4) On the related cylinder, replace the unserviceable FCM20 with the on line
spare.
5) Install a new FCM20 to the control box E90 in the on line spare position. This
new FCM20 becomes the on line spare.
6) Connect the power supply to the control box E90 and the related FCM20.
Note: The new on line spare in the control box E90 will receive a download of
all application data.
5. Recommended Procedure to Replace ALM-20
Note: You can do this procedure during engine operation, or when the engine
has stopped.
Do the procedure that follows:
1) Replace the defective ALM20.
2) Do a check of the function of the new ALM20 (outer LEDs), see 72181
ALM20 paragraph 5.
Regular Checks and Recommendations for WECS-9520
2014

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WinGD W-X82 and is the answer not in the manual?

WinGD W-X82 Specifications

General IconGeneral
BrandWinGD
ModelW-X82
CategoryEngine
LanguageEnglish

Related product manuals