Operation0110−1/A1
Winterthur Gas & Diesel Ltd.
2/ 3
19) Open the indicator valve on all cylinder covers.
WARNING
Injury Hazard: Before you operate the turning gear, make sure
that no personnel are near the flywheel.
20) Use the turning gear to turn the engine a minimum of one full turn to make sure
that all the running gears will operate correctly.
Note: Oil, water or fuel must not come out of the indicator valves.
21) If water oil or fuel comes out of the indicator valves, do a check of the related
cylinder liner, cylinder cover, piston or injection valves.
22) Set the cylinder lubrication to on.
23) Close the indicator valves on all cylinders.
24) Make sure that all the clamps lock the crankcase doors.
25) Make sure that the fuel pump regulating linkage moves freely in the spring links.
26) Check the pressure in the starting air bottles and open their drains until any
condensate has been drained.
27) Open the drain and test valve 2.06 to drain possible condensate water.
28) Close the drain and test valve 2.06.
29) Close the venting valves 2.21 and 2.27.
30) Open the shut-off valves on the starting air bottles 9.01.
31) Turn the handwheel 2.10 of the shut-off valve for starting air 2.03 to the position
AUTOMAT.
32) Make sure that the pressure gauges on the instrument panel show starting air
pressure and control air pressure.
33) Make sure that a pressure indication shows on the pressure gauges for the
control air supply.
The different circuits are:
D Air spring air
D Control air.
For the necessary pressures, see the Operating Data Sheet 0250−1.
34) Set the switches on the control panels for the auxiliary blowers to AUTOMAT.
35) Set to off the servo oil service pump.
36) Disengage the turning gear and lock the lever.
37) Open the test valve 2.06 of the shut-off valve for starting air 2.03 for a short time.
Make sure that you can hear the valve open.
38) Close the test valve 2.06.
Prepare for Engine Start after a Short Shut-down Period (One or More Days)