Operation
93081/A1
Winterthur Gas & Diesel Ltd.
9/ 10
From the ICC-INJ card, the firing pressure balancing function can be set ON as
follows:
Select [Shift] + [Arrow UP]
To confirm, select [Shift] + [Enter] (see the workflow in Fig. 12).
Fig. 12: Firing Pressure Balancing Set to ON Workflow
When the firing pressure control function is set to ON (see Fig. 13), the related Fuel
Quality Setting (FQS) is calculated by the ICC system and displayed in the top
left-hand corner of the ICC-INJ card (Fig. 9).
Fig. 13: Firing Pressure Control Set to ON
When the firing pressure control function is set to OFF (see Fig. 14), the fuel quality
setting is the same as shown on the flexView USER card adjusted by the operator.
Fig. 14: Firing Pressure Control Set to OFF