Operation
02502/A1
Winterthur Gas & Diesel Ltd.
3/ 4
Media Unit Location Signal No.
(1)
Func-
tion
(2)
Type of
signal
( 3)
Setting
Value
[bar or _C]
Time
Interval
[sec]
Condensate Level Water separator LS407172A ALM H max. 0
SLD H max. 60
before LS407576A ALM H max. 0
water separator SLD H max. 60
Starting air Pressure Engine inlet PT4301C ALM L 12.0 bar 0
Air spring air
8)
Pressure Distributor PT4341A ALM H 7.5 bar 0
ALM L 5.5 bar 0
SLD L 5.0 bar 60
PS4341S SHD LL 4.5 bar 0
Leakage oil from air spring air Level Exhaust valve air
spring
LS435152A ALM H max. 0
Control air normal supply
8)
Pressure Engine inlet PT4401A ALM L 6.0 bar 0
PT4411A ALM L 5.5 bar 0
stand-by supply
9)
Pressure Engine inlet PT4421A ALM L 5.0 bar 0
Fuel pump actuator Failure E98.1 XS5046A ALM F 0
E98.2 XS5047A ALM F 0
WECS9520 control system Power failure Power supply box
E85
XS5056A ALM F 0
Cylinder lubricating system Power failure Power supply box
E85
XS5058A ALM F 0
Engine performance data
overspeed
Speed Crankshaft ST511112S SHD H 110% 0
(1)
Signal number shows the interface to the remote control (see 46181).
(2)
Function:
SLD = Slow down
SHD = Shut down
ALM = Alarm.
(3)
Type of signal:
D = Difference in value
F = Failure
H = High
L = Low
LL = Very Low.
(4)
Alternative design.
(5)
Not included in standard engine supply range.
(6)
Abbreviations:
TC = Turbocharger
SAC = Scavenge Air Cooler.
(7)
For the location of measurements and signal numbers, see 80161 Servo
Oil Leakage and 80191 Fuel Leakage System.
(8)
Supply from board system for control and air spring air through the
pressure reducing valve 23HA.
201704
Alarms and Safeguards at Continuous Service Power