Operation02502/A1
Winterthur Gas & Diesel Ltd.
4/ 4
(9)
Supply from the starting air pipe upstream the shut-off valve for control and
air spring air through the pressure reducing valve 19HA (from starting air
bottles 9.01).
(10)
Signal designation changes downstream of the amplifier (on the engine)
from TExxxxA to TTxxxxA.
(11)
Alarm has an effect only above 30% engine power.
(12)
Alarm has an effect only above 40% engine power. Deviation from the
median (shows that there is no flow)
(13)
The alarm is not shown when the engine has stopped.
(14)
The alarm value is related to the turbocharger type. For more data, see the
documentation of the turbocharger manufacturer.
(15)
The alarm value can be different. For the applicable setting value, refer to
the specification of the damper manufacturer.
201704