4. Blocking of exhaust valve
The engine operation must be interrupted temporarily for blocking an exhaust
valve.
In case of an emergency, i.e. with water leakages into the combustion chamber
damper 32 (Fig. ’B’) can be removed and the exhaust valve blocked in open posi-
tion by means of pressure element GF 94259. The latter must also be fitted if an
exhaust valve is jammed in the open position (see 05201 in the Operating Manu-
al).
K
GF 94259
41
WCH01043
74.7 mm
V2 / 2013
Exhaust Valve: Dismantling and Assembling

Table of Contents