Maintenance
3130−1/A1
RT-flex58T-D
Winterthur Gas & Diesel Ltd.
3/ 4
SAMPLE CONTAINERS
HASSE & WREDE
B
3/8”BSF (M16)
3
KS
3
5
M10x1
PB
M10x1
4
KS
5/16”BSF (M10)
PB
8
8
007.964/97
Metaldyne
and STE
If a sample is not obtained by the method described, proceed as follows:
D Leave sample container in position.
⇒ Remove the opposite screw plug, connect a compressed air supply and apply
about 3.5 bar pressure.
D Only dried and filtered air may be used (connections and air hose must be
clean, free from any fouling).
⇒ As soon as fluid reaches open end of sample container shut off compressed
air supply and then fit one of the two cap nuts 8 to the sampling container.
⇒ Disconnect compressed air supply. Remove sample container and fit the
other cap nut 8.
⇒ Re-fit the corresponding screw plugs to all withdrawal openings.
⇒ Tighten and lock the screw plugs as already mentioned under ’Taking the
sample’.
Remark: The special sample container permits drawing a specific quantity of sili-
cone oil from the damper. The total number of samplings should be limited to 10.
2013
Taking a Silicone Fluid Sample