EasyManua.ls Logo

Xantrex XW - Using Quiet Time; Figure 4-3 Using the Quiet Time Feature

Xantrex XW
124 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
4–4 975-0307-01-01
Using Quiet Time
Use the Quiet Time feature to ensure that the XW Auto Generator Start
will not start the generator during the night or during times that conflict
with local noise restrictions.
Using Quiet Time involves three steps.
1. “QT En” must be set to [Enabled]. The default setting is [Enabled].
2. “QT Begin” must have an appropriate time set for Quiet Time to start
on schedule. The default setting for “QT Begin” is [9:00 PM] or
21:00 if using a 24-hour clock.
3. “QT End” must have an appropriate time set for Quiet Time to stop
on schedule. The default setting for “QT End” is [8:00 AM] or 8:00
on the 24-hour clock.
For more information about Quiet Time settings, see “QT En” on page 3–
7, “QT Begin” on page 3–8, and “QT End” on page 3–9.
To enable Quiet Time:
1. On the Auto Gen Start menu, use the navigation buttons to highlight
“QT En”.
2. Press Enter.
3. Use the navigation buttons to select [Enabled].
4. Press Enter.
To set the beginning of Quiet Time:
1. On the Auto Gen Start menu, use the navigation buttons to highlight
“QT Begin”, then press Enter.
2. Use the navigation buttons to select the hour, then press Enter.
Figure 4-3
Using the Quiet Time Feature
XW System
Home Screen
Select Device Menu
XW Auto Generator
Start Menu
Set Quiet Time
Parameters

Table of Contents

Related product manuals