Operation
4–4 975-0307-01-01
Using Quiet Time
Use the Quiet Time feature to ensure that the XW Auto Generator Start
will not start the generator during the night or during times that conflict
with local noise restrictions.
Using Quiet Time involves three steps.
1. “QT En” must be set to [Enabled]. The default setting is [Enabled].
2. “QT Begin” must have an appropriate time set for Quiet Time to start
on schedule. The default setting for “QT Begin” is [9:00 PM] or
21:00 if using a 24-hour clock.
3. “QT End” must have an appropriate time set for Quiet Time to stop
on schedule. The default setting for “QT End” is [8:00 AM] or 8:00
on the 24-hour clock.
For more information about Quiet Time settings, see “QT En” on page 3–
7, “QT Begin” on page 3–8, and “QT End” on page 3–9.
To enable Quiet Time:
1. On the Auto Gen Start menu, use the navigation buttons to highlight
“QT En”.
2. Press Enter.
3. Use the navigation buttons to select [Enabled].
4. Press Enter.
To set the beginning of Quiet Time:
1. On the Auto Gen Start menu, use the navigation buttons to highlight
“QT Begin”, then press Enter.
2. Use the navigation buttons to select the hour, then press Enter.
Figure 4-3
Using the Quiet Time Feature
XW System
Home Screen
Select Device Menu
XW Auto Generator
Start Menu
Set Quiet Time
Parameters

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xantrex XW and is the answer not in the manual?

Xantrex XW Specifications

General IconGeneral
Maximum Power Point Tracking (MPPT)Yes
ModelXW
CategoryController
Maximum PV Array Voltage150V
Nominal Battery Voltage48V
Output Voltage48V