10 Inspection, Maintenance, and Troubleshooting
10.1.5 Troubleshooting of Alarm and Warning
10-14
A.F5
Servomotor
Disconnection
Alarm
Occurred when the
control power sup-
ply was turned ON.
A SERVOPACK fault occurred. Replace the SERVOPACK.
A.F6
Occurred when the
servo was ON.
The servomotor power cable (U, V, W) was discon-
nect.
Correct the servomotor wiring.
A SERVOPACK fault occurred. Replace the SERVOPACK.
CPF00
Digital Opera-
tor Transmis-
sion Error 1
Occurred when the
power supply was
turned ON with dig-
ital operator con-
nected or
when connecting
digital operator with
the power supply
was turned ON.
The contact between the digital operator and the
SERVOPACK is faulty.
Insert securely the connector, or replace the cable.
The external noise interference occurred to the digi-
tal operator or cable.
(The digital operator cable is near noise source.)
Do not lay the cable near noise source.
Install digital operator far from noise source.
CPF01
Digital Opera-
tor Transmis-
sion Error 2
A digital operator fault occurred. Replace the digital operator.
A SERVOPACK fault occurred. Replace the SERVOPACK.
Table 10.5 Alarm Display and Troubleshooting (cont’d)
Alarm
Display
Alarm Name
Situation at Alarm
Occurrence
Cause Corrective Actions
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Other manuals for YASKAWA E-II Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA E-II Series and is the answer not in the manual?

YASKAWA E-II Series Specifications

General IconGeneral
BrandYASKAWA
ModelE-II Series
CategoryServo Drives
LanguageEnglish

Related product manuals