EasyManua.ls Logo

YASKAWA GA500 series - Page 209

YASKAWA GA500 series
526 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Details
2
2.4 C: Tuning
YASKAWA TOEPYAIGA5002A GA500 Programming 209
Figure 2.37 Example 1: Acceleration/Deceleration Rate (When C1-14 = 0 Hz, E1-04 = 60 Hz, and the Frequency Reference is
60 Hz)
When C1-14 0.0 Hz
C1-01, C1-03, C1-05, C1-07: Time to accelerate from 0 Hz to C1-14
C1-02, C1-04, C1-06, C1-08, C1-09: Time to decelerate from C1-14 to 0 Hz
Figure 2.38 Example 2: Acceleration/Deceleration Rate (When C1-14 = 40 Hz, E1-04 = 60 Hz, and the Frequency Reference
is 60 Hz)
Figure 2.39 Example 3: Acceleration/Deceleration Rate (When C1-14 = 80 Hz, E1-04 = 60 Hz, and the Frequency Reference
is 60 Hz)
Note:
Figure 2.37 to Figure 2.39 show the accel/decel times when C2-01 to C2-04 [S-Curve Times @ Start/End of Accel/Decel] = 0.00 s.
When L3-01 0 [Stall Prevention during Accel≠ Disabled], Stall Prevention could cause the acceleration time to be longer than the set
value.
When L3-04 0 [Stall Prevention during Decel Disabled], Stall Prevention could cause the deceleration time to be longer than the set
value.