Parameter Details
2
2.8 H: Terminal Function Selection
YASKAWA TOEPYAIGA5002A GA500 Programming 299
Figure 2.66 shows an example of how fast stop operates.
Figure 2.66 Fast Stop Time Chart
18: Timer Function
Setting Value Function Description
18 Timer Function
Sets the command to start the timer function. Use this setting with Timer Output [H2-xx = 12].
Note:
Refer to b4: Timer Function for more information.
19: PID Disable
Setting Value Function Description
19 PID Disable
Sets the command to disable PID control when b5-01 = 1 to 8 [PID Mode Setting = Enabled].
ON : PID control disabled
OFF : PID control enabled
1A: Accel/Decel Time Selection 2
Setting Value Function Description
1A Accel/Decel Time Selection
2
Set this function and H1-xx = 7[Accel/Decel Time Selection 1] together. Sets the drive to use Acceleration/Deceleration Time 3 [C1-
05, C1-06] or Acceleration/Deceleration Time 4 [C1-07, C1-08].
Note:
Refer to C1: Accel & Decel Time on page 204 for more information.
1B: Programming Lockout
Setting Value Function Description
1B Programming Lockout
Sets the command to prevent parameter changes when the terminal is OFF.
You can continue to view parameter setting values when the terminal is OFF [Parameters Cannot be Edited].
ON : Program Lockout
OFF : Parameter Write Prohibit
1E: Reference Sample Hold
Setting Value Function Description
1E Reference Sample Hold
Sets the command to sample the frequency reference at terminal A1 or A2, and hold the frequency reference at that frequency.
When the terminal is active for 100 ms, this function reads a sample of the analog frequency reference and holds that
sample. When you input the sample/hold command again, the function again reads a sample of the analog frequency
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV

Table of Contents

Other manuals for YASKAWA GA500 series

Related product manuals