11 Appendix
11.2.2 Parameters
11-22
Pn50A
Input Signal Selection 1 0000 to FFF1 2100 After restart Setup
Parameter
No.
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification
Reference
Section
0
1
Uses the sequence input signal terminals with standard allocation.
Changes the sequence input signal allocation for each signal.
Input Signal Allocation Mode (Refer to 3.3.1.)
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
ON when CN1-40 input signal is ON (L-level)
ON when CN1-41 input signal is ON (L-level)
ON when CN1-42 input signal is ON (L-level)
ON when CN1-43 input signal is ON (L-level)
ON when CN1-44 input signal is ON (L-level)
ON when CN1-45 input signal is ON (L-level)
ON when CN1-46 input signal is ON (L-level)
Sets signal ON.
Sets signal OFF.
OFF when CN1-40 input signal is OFF (H-level)
OFF when CN1-41 input signal is OFF (H-level)
OFF when CN1-42 input signal is OFF (H-level)
OFF when CN1-43 input signal is OFF (H-level)
OFF when CN1-44 input signal is OFF (H-level)
OFF when CN1-45 input signal is OFF (H-level)
OFF when CN1-46 input signal is OFF (H-level)
/S-ON Signal Mapping
Signal Polarity: Normal; Servomotor power ON when ON (L-level)
Signal Polarity: Reverse; Servomotor power ON when OFF (H-level)
(Refer to 5.2.1.)
0 to F Same as /S-ON
/P-CON Signal Mapping (P control when ON (L-level)) (Refer to 6.8.4.)
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Forward run allowed when CN1-40 input signal is ON (L-level)
Forward run allowed when CN1-41 input signal is ON (L-level)
Forward run allowed when CN1-42 input signal is ON (L-level)
Forward run allowed when CN1-43 input signal is ON (L-level)
Forward run allowed when CN1-44 input signal is ON (L-level)
Forward run allowed when CN1-45 input signal is ON (L-level)
Forward run allowed when CN1-46 input signal is ON (L-level)
Forward run prohibited
Forward run allowed
Forward run allowed when CN1-40 input signal is OFF (H-level)
Forward run allowed when CN1-41 input signal is OFF (H-level)
Forward run allowed when CN1-42 input signal is OFF (H-level)
Forward run allowed when CN1-43 input signal is OFF (H-level)
Forward run allowed when CN1-44 input signal is OFF (H-level)
Forward run allowed when CN1-45 input signal is OFF (H-level)
Forward run allowed when CN1-46 input signal is OFF (H-level)
P-OT Signal Mapping (Overtravel when OFF (H-level)) (Refer to 5.2.3.)
(Refer to 3.3.1)
(Refer to 5.2.1)
(Refer to 6.9.4)
(Refer to 5.2.3)