3.2 Specifications and Ratings
3.2.2 Ratings
3-9
3
Specications, Ratings, and External Dimensions of SGM7D Servomotors
Note: 1. These values are for operation in combination with a SERVOPACK when the temperature of the armature
winding is 20°C. These are typical values.
2. For the bearings used in these Servomotors, the loss depends on the bearing temperature. The amount of
heat loss is higher at low temperatures.
F
Where F is the external force,
Thrust load = F + Load mass
Moment load = F × L
Where F is the external force,
Thrust load = F + Load mass
Moment load = 0
Where F is the external force,
Thrust load = Load mass
Moment load = F × L
Reverse
Forward
Thrust load direction
Reverse
Forward
Thrust load direction
F
L
F
L