8 Monitor Modes (Un)
8.6.1 Displaying Output Signal Status
8-8
8.6 Monitoring Output Signals
The status of output signals can be checked with the input signal monitor (Un006). The procedure for display-
ing the status, the method of reading the monitor, and a display example are shown below.
8.6.1 Displaying Output Signal Status
Use the following steps to display the output signal status.
8.6.2 Interpreting Output Signal Display Status
The status of allocated signals is displayed on the 7-segment display on the Panel Operator.
When the output is in OFF (open) status, the top segment (LED) is lit.
When the output is in ON (short-circuited) status, the bottom segment (LED) is lit.
8.6.3 Output Signal Display Example
Output signals are displayed as shown below.
When ALM signal operates (alarm at H level)
Step
Display after
Operation
Keys Operation
1 Press the MODE/SET Key to select the monitor mode.
2 Press the UP or DOWN Key to select Un006.
3
Output signal display
status
The present status can be displayed on the 7-segment dis-
play on the Panel Operator by pressing the DATA/SHIFT
Key for approximately one second. Refer to 8.6.2 Interpret-
ing Output Signal Display Status.
4
Press the DATA/SHIFT Key for approximately one second
to return to the display of step 2.
MODE
/
SET
DATA
/
MODE
/
SET
DATA
/
MODE
/
SET
DATA
/
MODE
/
SET
DATA
/
Display LED
Number
Output Terminal Name
Signal Name
(Factory Setting)
1
CN1-31
,
-32
ALM
2 CN1-25, -26 (can be allocated.) /COIN or /V-CMP
3
CN1-27,
-28 (can be allocated.)
/TGON
4 CN1-29, -30 (can be allocated.) /S-RDY
5 CN1-37 ALO1
6 CN1-38 ALO2
7 CN1-39 ALO3
8 Reserved
4321
Top: OFF(H level)
Bottom: ON(L level)
Number
675
The top segment of
number 1 is lit.
7654321