A.b33:
Current Detection 
Error 3
(Current detector)
The detection circuit for the cur-
rent is faulty.
−
Turn the power supply OFF and 
then ON again. If the alarm still 
occurs, the SERVOPACK may be 
faulty. Replace the SERVOPACK.
The servomotor main circuit 
cable is disconnected.
Check for disconnection of the 
motor main circuit cable.
Correct the servomotor wiring.
A.bF0:
System Alarm 0
A SERVOPACK fault occurred. −
Turn the power supply OFF and 
then ON again. If the alarm still 
occurs, the SERVOPACK may be 
faulty. Replace the SERVOPACK.
A.bF1:
System Alarm 1
A SERVOPACK fault occurred. −
Turn the power supply OFF and 
then ON again. If the alarm still 
occurs, the SERVOPACK may be 
faulty. Replace the SERVOPACK.
A.bF2:
System Alarm 2
A SERVOPACK fault occurred. −
Turn the power supply OFF and 
then ON again. If the alarm still 
occurs, the SERVOPACK may be 
faulty. Replace the SERVOPACK.
A.bF3
:
System Alarm 3
A SERVOPACK fault occurred. −
Turn the power supply OFF and 
then ON again. If the alarm still 
occurs, the SERVOPACK may be 
faulty. Replace the SERVOPACK.
A.bF4:
System Alarm 4
A SERVOPACK fault occurred. −
Turn the power supply OFF and 
then ON again. If the alarm still 
occurs, the SERVOPACK may be 
faulty. Replace the SERVOPACK.
A.C10:
Servo Overrun 
Detected
(Detected when the 
servomotor power is 
ON.)
The order of phases U, V, and W 
in the servomotor wiring is incor-
rect.
Check the servomotor wiring.
Confirm that the servomotor is cor-
rectly wired.
An encoder fault occurred. −
If the alarm still occurs after turning 
the power OFF and then ON again, 
even though the servomotor is cor-
rectly wired, the servomotor may be 
faulty. Replace the servomotor.
A SERVOPACK fault occurred. −
Turn the power supply OFF and 
then ON again. If the alarm still 
occurs, the SERVOPACK may be 
faulty. Replace the SERVOPACK.
A.C80:
Absolute Encoder 
Clear Error and Multi-
turn Limit Setting Error
An encoder fault occurred. −
Turn the power supply OFF and 
then ON again. If the alarm still 
occurs, the servomotor may be 
faulty. Replace the servomotor.
A SERVOPACK fault occurred. −
Turn the power supply OFF and 
then ON again. If the alarm still 
occurs, the SERVOPACK may be 
faulty. Replace the SERVOPACK.
Alarm:
Alarm Name
Cause Investigative Actions Corrective Actions