2.8. External Force Monitor Output
The estimated external force values and sensor data are output to the M registers as shown below:
Estimated external torque values
for each axis
Estimated TCP external force
values
Sensor data for each axis (CH1)
Sensor data for each axis (CH2)
Also, you can check these values on the programming pendant by selecting {SAFETY FUNC.} -
{External Force Monitor} from the programming pendant main menu.
Maximum value reset button
- Press to reset all the force/torque maximum
values to zero.
Maximum value
- Displays the maximum of the absolute value
of the accumulated force/torque values.
Estimated external torque values
for each axis
Estimated TCP external force values
Monitor screen exit button
- Press to exit from the monitor screen.
Sensor output data for each axis
External force judgment marks
- A black circle (●) appears if the
force/torque exceeds the limit.
A white circle (○) appears if the
force/torque is within the limit.