HW1484764
Alarm List
7-8
HW1484764
(1) Turn off and on the power.
(2) If the alarm recurs, replace the ASF04 board. Save
CMOS.BIN before replacing the board.
If the alarm recurs after you have taken the action
described above, save CMOS.BIN and send the
description of when and how the alarm occurred
(operating steps, etc.) to your YASKAWA
representative.
TOOL NUMBER
UNMATCH
DETECTION (PFL)
Subcode:
Setting file
number
(1) Turn off and on the power.
(2) If the alarm recurs, replace the ASF01 board. Save
CMOS.BIN before replacing the board.
If the alarm recurs after you have taken the action
described above, save CMOS.BIN and send the
description of when and how the alarm occurred
(operating steps, etc.) to your YASKAWA
representative.
TRQ SENSOR
ERROR
NOTIFICATION
Subcode:
Shows the
cause of
the error.
(1) Turn off and on the power.
(2) If the alarm recurs, replace the ASF04 board. Save
CMOS.BIN before replacing the board.