5-13
IM 701310-17E
Commands
1
2
3
4
5
6
App
Index
Command Function Page
:GONogo:ZPARameter?
Queries all settings related to zone/parameter determination. 5-94
:GONogo:ZPARameter:SELect<x>?
Queries all settings related to the condition of the zone/parameter
determination.
5-94
:GONogo:ZPARameter:SELect<x>:
MODE
Sets the mode of the condition or queries the current setting. 5-94
:GONogo:ZPARameter:SELect<x>:
PARameter?
Queries all settings related to the condition parameter. 5-95
:GONogo:ZPARameter:SELect<x>:
PARameter:CATegory
Sets the parameter category or queries the current setting. 5-95
:GONogo:ZPARameter:SELect<x>:
PARameter:FFT<x>?
Queries all settings related to the FFT determination. 5-95
:GONogo:ZPARameter:SELect<x>:
PARameter:FFT<x>:CALCulation<x>
Sets the upper and lower limits of the calculation item of the FFT
determination or queries the current setting.
5-95
:GONogo:ZPARameter:SELect<x>:
PARameter:FFT<x>:PEAK?
Queries all settings related to the peak value of the FFT determination. 5-95
:GONogo:ZPARameter:SELect<x>:
PARameter:FFT<x>:PEAK:
DFREquency
Sets the upper and lower limits between the peak frequencies of the FFT
determination or queries the current setting.
5-95
:GONogo:ZPARameter:SELect<x>:
PARameter:FFT<x>:PEAK:DV
Sets the upper and lower limits between the peak voltages of the FFT
determination or queries the current setting.
5-96
:GONogo:ZPARameter:SELect<x>:
PARameter:FFT<x>:PEAK:
FREQuency<x>
Sets the upper and lower limits of the peak frequency of the FFT
determination or queries the current setting.
5-96
:GONogo:ZPARameter:SELect<x>:
PARameter:FFT<x>:PEAK:V<x>
Sets the upper and lower limits of the peak voltage of the FFT determination
or queries the current setting.
5-96
:GONogo:ZPARameter:SELect<x>:
PARameter:MEASure?
Queries all settings related to the determination using automated
measurement of waveform parameters (measure determination).
5-96
:GONogo:ZPARameter:
SELect<x>:PARameter:MEASure:
CALCulation<x>
Sets the upper and lower limits of the calculation item of the measure
determination or queries the current setting.
5-96
:GONogo:ZPARameter:SELect<x>:
PARameter:MEASure:STATistics
Sets the statistical value of the measure determination or queries the current
setting.
5-97
:GONogo:ZPARameter:SELect<x>:
PARameter:MEASure:TRACe<x>?
Queries all settings related to the trace of the measure determination. 5-97
:GONogo:ZPARameter:SELect<x>:
PARameter:MEASure:TRACe<x>:
AREA<x>?
Queries all settings related to the area of the measure determination. 5-97
:GONogo:ZPARameter:SELect<x>:
PARameter:MEASure:TRACe<x>:
AREA<x>:TYPE?
Queries all settings related to the waveform parameters of the measure
determination.
5-97
:GONogo:ZPARameter:SELect<x>:
PARameter:MEASure:TRACe<x>:
AREA<x>:TYPE:<Parameter>
Sets the upper and lower limits of the waveform parameter of the measure
determination or queries the current setting.
5-97
:GONogo:ZPARameter:SELect<x>:
PARameter:XY<x>?
Queries all settings related to the XY determination. 5-98
:GONogo:ZPARameter:SELect<x>:
PARameter:XY<x>:XYINteg
Sets the upper and lower limits integral value of the XY determination or
queries the current setting.
5-98
:GONogo:ZPARameter:SELect<x>:
RECTangle?
Queries all settings related to the rectangle determination. 5-98
:GONogo:ZPARameter:SELect<x>:
RECTangle:HORizontal
Sets the horizontal position of the rectangle used in the rectangle
determination or queries the current setting.
5-98
:GONogo:ZPARameter:SELect<x>:
RECTangle:VERTical
Sets the vertical position of the rectangle used in the rectangle determination
or queries the current setting.
5-98
:GONogo:ZPARameter:SELect<x>:
TRACe
Sets the source trace of the zone/parameter determination or queries the
current setting.
5-98
:GONogo:ZPARameter:SELect<x>:
WAVE?
Queries all settings related to the wave determination. 5-98
:GONogo:ZPARameter:SELect<x>:
WAVE:EDIT<x>:EXIT
Exits the edit menu of the wave determination zone. 5-99
:GONogo:ZPARameter:SELect<x>:
WAVE:EDIT<x>:PART
Editing the portion of the zone of the wave determination. 5-99
:GONogo:ZPARameter:SELect<x>:
WAVE:EDIT<x>:WHOLe
Sets the editing of the entire zone of the waveform zone. 5-99
:GONogo:ZPARameter:SELect<x>:
WAVE:TRANge
Sets the determination range of the zone determination or queries the
current setting.
5-99
5.1 List of Commands

Table of Contents