EasyManuals Logo

YOKOGAWA DL9040 User Manual

YOKOGAWA DL9040
256 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #51 background imageLoading...
Page #51 background image
5-17
IM 701310-17E
Commands
1
2
3
4
5
6
App
Index
Command Function Page
:MATH<x>:FILTer:RESCaling:
BVALue
Sets rescaling offset B of the filter or queries the current setting. 5-116
:MATH<x>:FILTer:TYPE
Sets the filter type or queries the current setting. 5-116
:MATH<x>:INTegral?
Queries all settings related to the integral computation. 5-116
:MATH<x>:INTegral:PSCaling?
Queries all settings related to the pre-scaling of the integral computation. 5-116
:MATH<x>:INTegral:PSCaling:
AVALue
Sets pre-scaling coefficient A of the integral computation or queries the
current setting.
5-116
:MATH<x>:INTegral:PSCaling:
BVALue
Sets pre-scaling offset B of the integral computation or queries the current
setting.
5-116
:MATH<x>:INTegral:RESCaling?
Queries all settings related to the rescaling of the integral computation. 5-116
:MATH<x>:INTegral:RESCaling:
AVALue
Sets rescaling coefficient A of the integral computation or queries the current
setting.
5-116
:MATH<x>:INTegral:RESCaling:
BVALue
Sets rescaling offset B of the integral computation or queries the current
setting.
5-116
:MATH<x>:INVert
Turns ON/OFF the inverted display of the computed waveform or queries the
current setting.
5-116
:MATH<x>:IPOint? (Initial Point)
Queries all settings related to the computation reference point. 5-117
:MATH<x>:IPOint:JUMP
Moves the computation reference point to the specified position. 5-117
:MATH<x>:IPOint:POSition
Sets the computation reference point or queries the current setting. 5-117
:MATH<x>:LABel?
Queries all settings related to the label of the computed waveform. 5-117
:MATH<x>:LABel[:DEFine]
Sets the label of the computed waveform or queries the current setting. 5-117
:MATH<x>:LABel:MODE
Turns ON/OFF the label display of the computed waveform or queries the
current setting.
5-117
:MATH<x>:MINus?
Queries all settings related to the subtraction. 5-117
:MATH<x>:MINus:PSCaling<x>?
Queries all settings related to the pre-scaling of the subtraction. 5-117
:MATH<x>:MINus:PSCaling<x>:
AVALue
Sets pre-scaling coefficient A of the subtraction or queries the current setting. 5-117
:MATH<x>:MINus:PSCaling<x>:
BVALue
Sets pre-scaling offset B of the subtraction or queries the current setting. 5-117
:MATH<x>:MINus:RESCaling?
Queries all settings related to the rescaling of the subtraction. 5-118
:MATH<x>:MINus:RESCaling:AVALue
Sets rescaling coefficient A of the subtraction or queries the current setting. 5-118
:MATH<x>:MINus:RESCaling:BVALue
Sets rescaling offset B of the subtraction or queries the current setting. 5-118
:MATH<x>:MULTiple?
Queries all settings related to the multiplication. 5-118
:MATH<x>:MULTiple:PSCaling<x>?
Queries all settings related to the pre-scaling of the multiplication. 5-118
:MATH<x>:MULTiple:PSCaling<x>:
AVALue
Sets pre-scaling coefficient A of the multiplication or queries the current
setting.
5-118
:MATH<x>:MULTiple:PSCaling<x>:
BVALue
Sets pre-scaling offset B of the multiplication or queries the current setting. 5-118
:MATH<x>:MULTiple:RESCaling?
Queries all settings related to the rescaling of the multiplication. 5-118
:MATH<x>:MULTiple:RESCaling:
AVALue
Sets rescaling coefficient A of the multiplication or queries the current setting. 5-118
:MATH<x>:MULTiple:RESCaling:
BVALue
Sets rescaling offset B of the multiplication or queries the current setting. 5-119
:MATH<x>:OPERation
Sets the operator or queries the current setting. 5-119
:MATH<x>:PLUS?
Queries all settings related to the addition. 5-119
:MATH<x>:PLUS:PSCaling<x>?
Queries all settings related to the pre-scaling of the addition. 5-119
:MATH<x>:PLUS:PSCaling<x>:
AVALue
Sets pre-scaling coefficient A of the addition or queries the current setting. 5-119
:MATH<x>:PLUS:PSCaling<x>:
BVALue
Sets pre-scaling offset B of the addition or queries the current setting. 5-119
:MATH<x>:PLUS:RESCaling?
Queries all settings related to the rescaling of the addition. 5-119
:MATH<x>:PLUS:RESCaling:AVALue
Sets rescaling coefficient A of the addition or queries the current setting. 5-119
:MATH<x>:PLUS:RESCaling:BVALue
Sets rescaling offset B of the addition or queries the current setting. 5-119
:MATH<x>:POSition
Sets the vertical position of the computed waveform or queries the current
setting.
5-120
:MATH<x>:SCALe?
Queries all settings related to scaling. 5-120
:MATH<x>:SCALe:CENTer
Sets the offset of the computed waveform or queries the current setting. 5-120
:MATH<x>:SCALe:MODE
Sets the scaling mode or queries the current setting. 5-120
:MATH<x>:SCALe:SENSitivity
Sets the vertical sensitivity of the computed waveform or queries the current
setting.
5-120
:MATH<x>:SELect
Sets the display option or queries the current setting. 5-120
:MATH<x>:SVALue (Scale VALUE)
Turns ON/OFF the scale value display or queries the current setting. 5-120
5.1 List of Commands