LimittotheNumberofRecordingChannelsinEachMeasurementMode
I/Ochannel+mathchannel+communicationchannel
Model Measurment
mode
Recordinginterval
1ms 2ms 5ms 10ms 20ms 50ms 100ms 200ms 500ms 1sor
more
GP10 Normal – – – – – – 100 100 100 100
High speed 2 4 10 20 40 100 100 100 100 100
Dualinterval – – 5 10 20 50 100 100 100 100
GP20-1 Normal – – – – – – 100 200 500 500
High speed 2 4 10 20 40 100 100 200 500 500
Dualinterval – – 5 10 20 50 100 100 250 250
GP20-2 Normal – – – – – – 500 500 1000 1000
High speed 10 20 50 100 150 150 200 500 1000 1000
Dualinterval 5 10 25 40 50 50 100 20 600 600
NotesonModuleInstallation
•WhenthereferencejunctioncompensationofthisproductisusedwiththethermocoupleinputofaGX90XA-10-U2,
GX90XA-10-L1,GX90XA-10-T1orGX90XA-04-H0,ifthefollowingmoduleisinstalledtotheright(slotwiththe
smallernumber)oftheGX90XAmoduleasseenfromtheGPrearpanel,thereferencejunctioncompensation
accuracyofthatmodulemaydeviatefromtheguaranteedrange(exceptwhenGX90XA-04-H0isinstalledto
adjacentslots).
 GX90XA-10-C1,GX90XA-04-H0,GX90WD,GX90YA,GX90UT
•OntheGP20,whenthereferencejunctioncompensationofthisproductisusedwiththethermocoupleinputofa
GX90XA-10-U2,GX90XA-10-L1,GX90XA-10-T1,orGX90XA-04-H0,ifthefollowingmoduleisinstalledabove,
below,totheright,ortotheleft(slotwiththesmallernumber)oftheGX90XAmoduleasseenfromtheGPrear
panel,thereferencejunctioncompensationaccuracyofthatmodulemaydeviatefromtheguaranteedrange.
 GX90YA,GX90UT
•IfyouwanttousetheDIofaGX90XDorGX90WD,onlyasinglemoduleinstalledintheGPmainunitcanbeused.
•IfthemaximumnumberofI/Ochannelsareassignedandthelastchannelisassignedtoanintermediatechannelof
aconnectedI/Omodule,thatmoduleandsubsequentmoduleswillnotberecognized.
Module
n
• • •
1
10
Module
1
:
81
90
:
91
100
106
:
:
Maximum
number of I/O
channels
This module will not be detected.
Example GP10/GP20-1
DualIntervalFileSearchingofUniversalViewer
Recordingmode Linkdualintervalwaveform
*1
Showdualintervalintegratedlink
view
*2
Free+Free
 
Free+Trigger(single/repeat) – –
Trigger(single/repeat)+Trigger(single/
repeat)
– –
*1 Linkdualintervalwaveform:Afunctionthatsearchesafolderforanddisplaysthelethatformsapairwiththedisplayed
le.
*2 Showdualintervalintegratedlinkview:AfunctionthatdisplaysfromtheresultofSearchOpenoneofthelesthatformsa
pair and displays both trends when it is clicked.
PIDprogrampatternsettingfromtheWebapplication
YoucannotsetfromtheWebapplication.HardwareConguratorisrequiredforsettingprogrampatterns.