84 R110Xi/R170Xi User Guide 12/6/04 23063L-003 Rev. 1
RFID Guidelines
^RF
Examples •
Write ASCII
This example writes 96-bit data.
^XA
^RS4
^RFw,a^FD00 my data^FS
^XZ
Write Hex
This example writes 64-bit data.
^XA
^RS3
^RFW,H^FD1122334455667788^FS
^XZ
Write EPC
This example writes 96-bit data, as specified by the
^RB command.
^XA
^RB96,8,3,3,20,24,38
^RFw,e^FD16,3,5,78742,146165,1234567891^FS
^XZ