Troubleshooting
Printer Diagnostics
23063L-003 Rev. 1 12/6/04 R110Xi/R170Xi User Guide 139
FEED and PAUSE Self Test
Performing this self test temporarily resets the printer configuration to the factory default
values. These values are active only until power is turned off unless you save them
permanently in memory.
To perform a FEED and PAUSE self test, complete these steps:
1. Turn Off (O) the printer.
2. Press and hold FEED and PAUSE while turning the power On (I). Hold FEED and
PAUSE until the DATA light turns off.
No labels print at the end of this test.
Communications Diagnostics Test
This test is controlled from the front panel display. See Setting Communications Mode
on page 52. Figure 54 shows a typical printout from this test. Turn off the power to exit this
self test and return to normal operation.
Figure 54 • Communications Diagnostics Test Label
Additional Printer Diagnostics
Additional diagnostic tests are available for this printer. See the Maintenance Manual for
information about these additional tests.
Note • The communications test label prints upside-down.

Table of Contents

Other manuals for Zebra R110Xi

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra R110Xi and is the answer not in the manual?

Zebra R110Xi Specifications

General IconGeneral
BrandZebra
ModelR110Xi
CategoryPrinter
LanguageEnglish

Related product manuals