Getting Started
25
• 5-Slot Ethernet Cradle
• 5-Slot Charge Only Cradle with 4-Slot Battery Charger
• 5-Slot Ethernet Cradle with 4-Slot Battery Charger.
The 6,700 mAh battery charges from 0 - 90% in less than four hours at room temperature.
The 7,000 mAh battery charges from 0 - 90% in less than five hours at room temperature.
Charge batteries in temperatures from 0 °C to 40 °C (32 °F to 104 °F). The device or accessory always
performs battery charging in a safe and intelligent manner. At higher temperatures (e.g. approximately +37
°C (+98 °F)) the device or accessory may for small periods of time alternately enable and disable battery
charging to keep the battery at acceptable temperatures. The device or accessory indicates when charging
is disabled due to abnormal temperatures via its red blinking LED.
1. To charge the main battery, connect the charging accessory to the appropriate power source.
2. Insert the device into a cradle or attach to a cable. The device turns on and begins charging. The
Charging/Scan LED lights amber while charging, then turns solid green when fully charged.
IMPORTANT: When trying to power on the device, a quick blink of the charging LED indicates that it does
not have enough battery power to turn on. You will need to charge the battery or replace it.
Powering on the Device
The device starts automatically as soon as power is applied; either with a charged battery installed or when
inserted into the cradle.
If a charged battery is installed and the device is turned off, press the Power button to turn on.
When the device is powered on for the first time, it initializes its system. The splash
screen appears for a
short period of time.
Table 2 Charging/Scan LED Charging Indicators
State Indication
Off Device is not charging. Device is not inserted correctly in the cradle or connected
to a power source. Charger/cradle is not powered.
Solid Amber Healthy battery is charging.
Solid Green Healthy battery charging is complete.
Fast Blinking Red
(2 blinks/second)
Charging error, such as:
- Temperature is too low or too high.
- Charging has gone on too long without completion (typically eight hours).
Solid Red Unhealthy battery is charging or fully charged.