Diagnostics and Troubleshooting
130
Voided Labels (Continued)
Issue Possible Cause Recommended Solution
Low yields. Too many
RFID tags per roll are
voided.
The RFID labels are not within
specifications for the printer, which
means that the transponder is not
in an area that can be programmed
consistently.
Make sure that the labels meet transponder
placement specifications for your printer. See
http://www.zebra.com/transponders for transponder
placement information.
For more information, refer to the RFID Programming
Guide 3, or contact an authorized Zebra RFID
reseller.
Incorrect read and write power
levels.
Change the RFID read and write power levels. For
instructions, refer to the RFID Programming Guide 3.
Radio frequency (RF) interference
from another RF source.
Do one or more of the following as necessary:
Move the printer away from fixed RFID readers.
Make sure that the media door is closed at all
times during RFID programming.
The printer is using outdated
printer firmware and reader
firmware versions.
Go to http://www.zebra.com/firmware for updated
firmware.