Printer Configuration and Adjustment
80
Print > Sensors > Manual Calibration
Calibrate the printer to adjust the sensitivity of the media and ribbon sensors.
For complete instructions on how to perform a calibration procedure, see Calibrate the Ribbon
and Media Sensors on page 89.
Related ZPL command(s):
~JC
SGD command used:
ezpl.manual_calibration
Control panel key(s): Hold PAUSE + FEED + CANCEL for 2 seconds to initiate
calibration.
Printer web page: The calibration procedure cannot be initiated through the web
pages. See the following web page for settings that are set during
sensor calibration:
View and Modify Printer Settings > Calibration
IMPORTANT: Do not change these settings unless you
are told to do so by Zebra Technical Support or by an
authorized service technician.
Print > Sensors > Label Sensor
Set the sensitivity of the label sensor.
IMPORTANT: This value is set during sensor calibration. Do not change these settings
unless you are told to do so by Zebra Technical Support or by an authorized service
technician.
Accepted values: 0 to 255
SGD command used:
ezpl.label_sensor
Printer web page: View and Modify Printer Settings > Calibration
Print > Sensors > Sensor Type
Select the media sensor that is appropriate for the media that you are using. The reflective
sensor typically is used only for black mark media. The transmissive sensor typically is used for
other media types.
Accepted values: TRANSMISSIVE, REFLECTIVE
Related ZPL command(s):
^JS
SGD command used:
device.sensor_select
Printer web page: View and Modify Printer Settings > Media Setup