Chapter14EthernetOAMConguration
St-
ep
CommandFunction
18
ZXR10(config-md-ma)#assignmip<1-64>interface
<interfacename>
ThisassignsMIPtoport.
Theportcanberealportor
samartgroup.
WhenassigningportforMIP ,
theMEPthatlevelishigher
thanorequaltocurrentMIP
levelcan’texistontheportin
thesamevlansamelevel.
19
ZXR10(config-md-ma)#noassignmep<1-8191>Thiscancelstheassignment
ofMEPtoport.
20
ZXR10(config-md-ma)#noassignmip<1-64>Thiscancelstheassignment
ofMIPtoport.
21
ZXR10(config-md-ma)#mep<1-8191>state{enable|dis
able}
ThissetsMEPmanagement
enabled.Bydefault,CFMof
MEPisdisabled.
22
ZXR10(config-md-ma)#mep<1-8191>alarm-lowest-pri
<1-5>
ThissetsMEPalarmpriority.
Theveprioritiesfromlow
tohighareRDIalarm,MAC
alarm,RMEPCCMfailure
alarm,ERRCCMalarmand
XCONalarm.
23
ZXR10(config-md-ma)#mep<1-8191>priority<0-7>ThissetsMEPpriority.
<1-8191>:indexnumber
ofMEP
<0-7>:priorityofMEP ,the
rangeis0-7.
24
ZXR10(config-md-ma)#mep<1-8191>ccm-send
{enable|disable}
ThissetsCCpacketsending
enabled.
25
ZXR10(config-md-ma)#mep<1-8191>ccm-check{enabl
e|disable}
ThischecksCCpacket.
<1-8191>:IDnumberof
MEP
Enable:ccm-checkstatusof
enabledMEP
Diable:ccm-checkstatusof
disabledMEP
26
ZXR10(config-md-ma)#mep<1-8191>client-level<
0-7>
Thissetslevelvalueofclient
MEPandalarmfunctionuse.
CFMFunctionConfiguration
1.ToenableLBfunction,usethefollowingcommand.
LB(LoopBack)meansaMEPsendsadesignatedMPunicast
CFMPDUforfaultafrmationandisolation.AMPresponses
LBMandsendsunicastpackettoLBMinitiatorMEP .
WhenMPloopresponserreceivesaLBM,checkitsvalidity
rst,ifinvalidthendiscard.IfLBMsourceaddressismulti-
castaddress(notaloneMACaddress)ordestinationaddress
CondentialandProprietaryInformationofZTECORPORATION117