23.3.5 Remote Management Limitations
Remote management over LAN or WAN will not work when:
1 You have disabled that service in menu 24.11.
2 The IP address in the Secured Client IP field (menu 24.11) does not match the client IP
address. If it does not match, the ZyXEL Device will disconnect the session
immediately.
3 There is already another remote management session with an equal or higher priority
running. You may only have one remote management session running at one time.
23.4 System Timeout
There is a system timeout of five minutes (300 seconds) for Telnet/web/FTP connections. Your
ZyXEL Device will automatically log you out if you do nothing in this timeout period, except
when it is continuously updating the status in menu 24.1 or when sys stdio has been
changed on the command line.
Authenticate Client
Certificates
Select Yes by pressing [SPACE BAR]. The internal RADIUS server uses one
of the certificates listed in the My Certificates screen to authenticate each
wireless client. The exact certificate used depends on the certificate
information configured on the wireless client.
Once you have filled in this menu, press [ENTER] to save your configuration, or press [ESC] to cancel.
Table 81 Menu 24.11 Remote Management Control
FIELD DESCRIPTION

Table of Contents

Related product manuals