370 Parameters
99.15 Motor polepairs
calculated
Calculated number of pole pairs in the motor. 0
0…1000 Number of pole pairs. 1 = 1
99.16 Motor phase order Switches the rotation direction of motor. This parameter can
be used if the motor turns in the wrong direction (for example,
because of the wrong phase order in the motor cable), and
correcting the cabling is considered impractical.
Note:
Changing this parameter does not affect speed reference
polarities, so positive speed reference will rotate the motor
forward. The phase order selection just ensures that
“forward” is in fact the correct direction.
U V W
U V W Normal. 0
U W V Reversed rotation direction. 1
No. Name/Value Description Def/FbEq16