398 Additional parameter data
41.58 Set 2 increase prevention Binary
src
--1 = 1
41.59 Set 2 decrease prevention Binary
src
--1 = 1
41.60 Set 2 PID activation source Binary
src
--1 = 1
41.79 Set 2 units Real 0...31 Depends
on
selection
-
41.80 Set 1 PID output min source Analog
src
--1 = 1
41.81 Set 1 PID output max source Analog
src
--1 = 1
41.89 Set 2 setpoint multiplier Real -100000.00…100000.00 - 100 = 1
41.90 Set 2 feedback multiplier Real -100000.00…100000.00 - 100 = 1
43 Brake chopper
43.01 Braking resistor temperature Real 0.0…120.0 % 10 = 1%
43.06 Brake chopper enable List 0…3 - 1 = 1
43.07 Brake chopper runtime enable Binary
src
0...1 - 1 = 1
43.08 Brake resistor thermal tc Real 0…10000 s 1 = 1 s
43.09 Brake resistor Pmax cont Real 0.00…10000.00 kW 100 = 1 kW
43.10 Brake resistance Real 0.0…1000.0 Ohm 10 = 1 ohm
43.11 Brake resistor fault limit Real 0…150 % 1 = 1%
43.12 Brake resistor warning limit Real 0…150 % 1 = 1%
44 Mechanical brake control
44.01 Brake control status PB 0b0000…0b1111 - 1 = 1
44.06 Brake control enable Binary
src
--1 = 1
44.08 Brake open delay Real 0.00…5.00 s 100 = 1 s
44.13 Brake close delay Real 0.00…60.00 s 100 = 1 s
44.14 Brake close level Real 0.00…1000.00 rpm 100 = 1 rpm
45 Energy efficiency
45.01 Saved GW hours Real 0…65535 GWh 1 = 1 GWh
45.02 Saved MW hours Real 0…999 MWh 1 = 1 MWh
45.03 Saved kW hours Real 0.0…999.9 kWh 10 = 1 kWh
45.04 Saved energy Real 0.0…214748364.0 kWh 10 = 1 kWh
45.05 Saved money x1000 Real 0…4294967295 thousands INR 1 = 1
45.06 Saved money Real 0.00…999.99 INR 100 = 1
45.07 Saved amount Real 0.00…21474830.00 INR 100 = 1
45.08 CO2 reduction in kilotons Real 0…65535 metric
kiloton
1 = 1 metric
kiloton
45.09 CO2 reduction in tons Real 0.0…999.9 metric
ton
10 = 1 metric
ton
No. Name Type Range Unit FbEq32