Connector X50 (D8T and R8i modules)
# Description
9 Not in use.
8N
115/230 V AC (50/60 Hz) input for optional heating element
(option +C183)
7L
6 Not in use.
5N
115/230 V AC 50 Hz input for internal power supply (BDPS)
(115V AC 60 Hz with option +G304)
4L
3 W 400 V AC (50/60 Hz) supply for optional DOL (direct-on-line)
cooling fan (option +C188).
Note: In modules without +C188, the DOL wiring is present
but not in use.
2V
1U
Connector X50 (D7T module)
# Description
9
Not in use.
8
7
6
5N
115/230 V AC input for internal power supply (BDPS)
(115V with option +G304)
4L
3 PE 400 V AC (50/60 Hz) supply for optional DOL (direct-on-line)
cooling fan (option +C188).
Note: In modules without +C188, the DOL wiring is present
but not in use.
2N
1L
Connectors X51, X52, X53
# Name Description
X51 STO OUT I
nverter modules: STO signal forwarding
output to next inverter module (if present).
X52 STO IN I
nverter modules: STO signals from BCU
control unit
X53 24V OUT 24 V DC output (for BCU control unit)
Note: The Safe torque off (STO) safety function is only
implemented in inverter units. Therefore, the STO function can
not be used in supply and brake units. In supply and brake
units, de-energizing any connection of STO IN (X52) connector
stops the drive. Note that this stop in supply or brake module is
not safety related and must not be used in safety function
purposes.
STO OUT
X51
FE
GND
24V
GND
24V
STO IN
X52
FE
GND
24V
GND
24V
24V OUT
X53
FE
24V
GND
24V
GND