+01.1
=01
=-A51
BCU-02
SUPPLY CONTROL UNIT
9
MEMORY UNIT
-X205
10
SD CARD
-XPOW
1 2 3 4
+24VIN1
11 12 21 22 31 32
-V1T
-V1R
-V2T
-V2R
-X485
5 6 7 8
+10VREF
AGND
-XAI
1 2
-10VREF
3 4 5 6 7
-XAO
1 2 3 4
DEFAULT OUTPUT DESIGNATION
AO1, AO2; 0(4)...20mA
+24DI
-XD24
5 6 7 8
-XRO1
13
-XRO2
23
-XRO3
33
-XDI
1 2 3 4 5 6 7
DEFAULT INPUT DESIGNATION
DI1...DI6+DIIL; NOMINAL VOLTAGE 24VDC
-XDIO
1 3 2 4
DEFAULT INPUT/OUTPUT DESIGNATION
-X9
POWER STAGE LINKS
20
OPTION SLOTS
20 20
-SLOT1 -SLOT2 -SLOT3
CH1
CH2
-RO1
13
11
12
1 = RUNNING
-A51 RUNNING
+24V
-RO2
23
21
22
1 = NO FAULT
-A51 FAULT (-1)
+24V
-RO3
33
31
32
CONTROL
-A51 MAIN BREAKER
+24V
NO
NC
COM
NO
NC
COM
NO
NC
COM
-AI1
4
5
By default not in use
-A51 AI1 NOT SPECIFIED
0(2)...10V
+
-
-AI2
6
7
By default not in use
-A51 AI2 NOT SPECIFIED
0(4)...20mA
+
-
RELAY OUTPUT DESIGNATION
RO1...RO3; 250VAC, 6A/24VDC, 6A
-AO2
3
4
By default not in use
-A51 AO2 NOT SPECIFIED
0(4)...20mA <-->
-AO1
1
2
By default not in use
-A51 AO1 NOT SPECIFIED
0(4)...20mA <-->
+
AGND
+
AGND
-DI1
1
0 = FAULT
-A51 TEMPERATURE FAULT
-DI2
2
1 = RUN / ENABLE
-A51 RUN / ENABLE
-DI3
3
1 = CLOSED
-A51 MAIN BREAKER FB
-DI4
4
0 = FAULT
-A51 CIRCUIT BRK FAULT
-DI5
5
1 = NO FAULT
-A51 EARTH LEAKAGE
-DI6
6
1 = RESET
-A51 RESET
DCCOM
S7
+24DI
DCOM
0VD
-DIO1
1
By default not in use
-A51 DIO1 NOT SPECIFIED
0(4)...20mA
+
0VD
-DIO2
2
By default not in use
-A51 DIO2 NOT SPECIFIED
0(4)...20mA
+
0VD
0VIN1
+24VIN2
0VIN2
+24V
OUT1
SGND
24V DC IN1 FOR STO
IN1
IN2
24V DC IN2 FOR STO
-XSTO
1 2 3 4
SAFETY OPTION
20
COMMUNICATION OPTION
RDCO-04
-SLOT4
RS-485
FOR D2D LINK
DEFAULT INPUT DESIGNATION
AI1; 0(2)...10V/-10V...+10V
AI2; 0(4)...20mA
2 3
-XD2D
1
B
A
BGND
4
SHIELD
IN1
SGND
IN2
-XSTO.OUT
5 6 7 8
SGND
B
A
BGND
SHIELD
20
-X12
0VD
RJ45
NOT IN USE
-XETH
8
CONTROL PANEL
-X13
8
=-F22
12
14 11
020/6F
;A51.1:V1
005/2D
;A51.1:V2
;A51.2:V1
005/4D
;A51.2:V2
+01.1.8
=01
=-S21
1314
16A
RD32527
13
14
10D
23
24
=-S21
0
1
10
+01.1.8
=01
+02.1
=01
=-F6.1
12
=-F6.2
12
;A418.1:V16
040/15L
;A418.1:V15
=-Q2.2
1314
4B
=-Q2.1
1314
3B
=-F112.1
12
14 11
020/2G
+02.1
=01
12
001/10B
34
001/10G
56
001/10B
13 14
11B
21 22
31 32
43 44
12
001/9G
34
001/9A
56
001/9G
13 14
11B
21 22
31 32
43 44
+02.1
=01
;Q26:43
020/6J
;Q2.1:A2
020/9J
+01.1
=01
12
020/6G
34
56
13 14
020/6G
=-Q26
A2 A1
=-Q21
1314
001/5B
=-Q1.1
1314
001/6G
+01.1
=01
;A51.XRO3:L
020/6J
DSU 1 DSU 2
;TF.1:2
020/7C
;TF.1:1
020/7C
ON
OFF N
COM
PLC PLC
AB
S1
=-Q2.2
ON
OFF N
COM
PLC PLC
AB
S1
=-Q2.1
;Q26:A2
020/9J
43 44
2B
21 22
V21
YELLOW
POWER OK
V22
GREEN
BATTERY OK
V23
GREEN
WRITE
V24
RED
FAULT
AI1 I/U SELECTION
S4
I
U
AI2 I/U SELECTION
S5
I
U
D2D LINK
S6
ON
OFF
GROUND SELECTION
S7
ON
OFF
TERMINATION
DICOM = DIOGND
=-X99
41
=-X99
42
=-X99
31
+01.1
=01
43 44
3D
=-Q26
53 54
3D
53 54
2B
31 32
;A41:X13
040/8H
20
=-A518.1
-V13
-X33
-V20
-V19
-V18
-V17
-V16
-V15
-V14
DDCS COMMUNICATION
RDCO-04
TERMINATION
SWITCH S1
TERMINATED
OPEN
=-A57
-X100
-X1
-X2
-X3
FDPI-02
DIAGNOSTICS AND PANEL INTERFACE
8
;A51:24VDC
005/2C
;A51:GND
-DIIL
0 = ACTUATED
-A51 DIGITAL INTERLOCK
By default not in use
=-A51_MEM
MEMORY
UNIT
SD CARD
3AXD10000268938 050
060
050.DWG
2xD7T+2xR8i 12 pulse
ACS880-04-0800A-7+A004+A018+C183+C188
Supply Control Board
Circuit Diagram
EN
Vanin Oleg10.08.2018
Asikainen Mika10.08.2018
ABB Drives
=-Q1.1
3334
001/6G
001/8B
001/8G
+01.1.8
=01
DOOR
=-A58
-X100
-X101
-X102
-X103
DPMP-01
PANEL KIT
6
=-A59
X3
USB
CONTROL PANEL
ACS-AP-W
8