ControlMaster CM15 and CMF160
Universal process indicator
1
/8 DIN 7 Advanced Level
IM/CM/I–EN Rev. P 35
…Device Setup / …Initial Setup
Config Action The Config Action parameter is used to determine how the indicator and indicator outputs behave
when the Advanced level is entered – see page 34.
Continue The indicator continues to operate as in Operator level. Outputs continue to operate as normal.
Hold Digital, relay and analog outputs are held at their value / state when Configuration mode is
entered. When the Advanced level is exited, the indicator returns to the pre-Configuration mode
of operation.
Inactive Analog outputs are set to 0 mA. Relays de-energized, digital outputs inactive.
Level 1 (2) Indicator* Note. Applicable to level applications only.
Specific Gravity Value of the specific gravity currently applied to the process variable.
Volume Constant The constant used to calculate the volume (maximum value 999.9).
Volume Units The unit of measure used to calculate the volume.
Volume DPs The number of decimal places required (maximum of 4).
*See Section 8.2.4, page 84 for examples of volume calculations.