EasyManua.ls Logo

ABB DCS880 series - Page 103

ABB DCS880 series
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
103
3ADW000462R0401 DCS880 Hardware manual e d
Layout
SDCS-BAB-F01 for module sizes H1 and H2:
SDCS-BAB-F02 for module sizes H3 and H4:
Location
The SDCS-BAB-F0x is located between the power part and the control board SDCS-CON-H01.
Functions
The SDCS-BAB-F0x is a three-phase half-controlled field exciter. The field exciter is directly supplied from the
armature mains. Its firing pulses and snubbers are located on the
SDCS-PIN-H01. For connection details see next pages.
Number of threads through the hole in the T100 (e.g. 3 threads equal 2 loops).
Size Converter type Used type Used fuses T100 threads I
F
[A]
H1 DCS880-S01-0020 ...
DCS880-S02-0025
SDCS-BAB-F01 F100 ... F102 on SDCS-PIN-H01
KTK 25 = 25 A
4 0.3 ... 6
H1 DCS880-S01-0045 ...
DCS880-S02-0100
SDCS-BAB-F01 F100 ... F102 on SDCS-PIN-H01
KTK 25 = 25 A
3 1 ... 12
H2 DCS880-S01-0135 ...
DCS880-S02-0300
SDCS-BAB-F01 F100 ... F102 on SDCS-PIN-H01
KTK 25 = 25 A
2 1 ... 18
H3 DCS880-S01-0315 ...
DCS880-S02-0520
SDCS-BAB-F02 F100 ... F102 on SDCS-PIN-H01
KTK 25 = 25 A
1 2 ... 25
H4 DCS880-S01-0610 ...
DCS880-S02-1000
SDCS-BAB-F02 F401 ... F403 in drive
KTK 30 = 30 A
1 2 ... 30
X6
X10
X15
X5
X3 X2 X1
X4
21
1
F+ F-
T100
SF_BABF_001_a.ai
SF_BABF_001_a.ai
X6
X10
X15
X5
X3 X2 X1
X4
21
1
T100
X10 : F-
X10 : F+

Table of Contents

Other manuals for ABB DCS880 series

Related product manuals