EasyManuals Logo

ABB DCS880 series Hardware Manual

ABB DCS880 series
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #125 background imageLoading...
Page #125 background image
Dimensions and weights
125
3ADW000462R0401 DCS880 Hardware manual e d
Size H7
(+P906)
DCS880-S0b-1900
DCS880-S0b-2050
DCS880-S0b-2500
DCS880-S0b-3000
With external control unit
(+P906)
Control unit
Power unit
225
270
350
370,5
10 , 5
Earthing M6
MG_880_007_Control unit_a.ai
For M6
250
375
425
458,2
10x 20
2
C
D
U
V
W
C
D
U
V
W
0
SDCS-OPL-H01
1
7
2
5
385
445
1
5
10x 20
3
Air entry
55
72 100
6
3
Ear t hing M10
7
5
9
,
5
2
0
0
2
0
0
2
0
0
2
2
5
1
7
5
0
62
40
5
0
M1 2
409
468,2
1
3
6
Air outlet
MG_880_008_H7_a.ai
From the front, right,
left and back

Table of Contents

Other manuals for ABB DCS880 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB DCS880 series and is the answer not in the manual?

ABB DCS880 series Specifications

General IconGeneral
Cooling MethodAir-cooled, liquid-cooled
Control TypeDirect Torque Control (DTC)
Communication ProtocolsEthernet, Modbus RTU, Modbus TCP, PROFIBUS DP, PROFINET, EtherCAT
Protection ClassIP00, IP21, IP54
SafetySTO (Safe Torque Off)
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature
Ambient Temperature-20 to +55 °C (derating may apply)
Input Voltage3-phase, 380-830 V AC