Technical data
102
3ADW000462R0401 DCS880 Hardware manual e d
Field circuit interfaces SDCS-BAB-F01 and SDCS-BAB-F02 (H1 ... H4)
The OnBoard field exciter is located internally. The firing pulses are synchronized using the mains circuit L1,
L2, L3 and the SDCS-CON-H01. The pulses are amplified on the SDCS-PIN-H01.
The hardware structure is a three phase half controlled bridge supplied directly from the mains U1, V1, W1 via
fuses F100, F101, F102.
If the OnBoard field exciter is not needed it can be deselected in the firmware.
The field circuit interface consists of:
Firing the three phase half controlled field bridge.
Measuring the field current on the DC side. The scaling is automatically selected using the rated
motor field current.
The snubber circuit is shared with the armature bridge.
Fuses F100, F101, F102 are used for cable and motor field winding protection.
Size H3 and H4 converters for 600 V are always delivered without OnBoard field exciter.
Size H5 converters do not use the field circuit interface on the SDCS-PIN-H01
Ratings OnBoard field exciter
Cables
AC voltage range 110 ... 500 V (IEC) / 525 V (UL)
AC insulation voltage 600 V
Frequency 50 Hz / 60 Hz
AC input current < Field current
Size H1 H1 H2 H3 H4
DC output current 6 A / 12 A 12 A 18 A 25 A 30 A
max. cross sectional area 6 mm²
AWG 10
6 mm²
AWG 10
6 mm²
AWG 10
6 mm²
AWG 10
6 mm²
AWG 10
min. cross sectional area 1 mm²
AWG 16
2.5 mm²
AWG 13
4 mm²
AWG 11
6 mm²
AWG 10
6 mm²
AWG 10