Technical data
80
3ADW000462R0401 DCS880 Hardware manual e d
The converter module and enclosed converter components are designed for use in industrial environments. In
EEA countries, the components fulfil the requirements of the EU directives, see table below:
Effect of site elevation and ambient temperature on the converter‘s load capacity
Current reduction to % of nominal converter current
European Union Directive Manufacturer's Assurance Harmonized Standards
Converter module
Machinery Directive
2006/42/EC Declaration of Incorporation
[IEC 60204-1]
Low Voltage Directive
2014/35/EU Declaration of Conformity EN 61800-1
[IEC 61800-1]
EN 60204-1
[IEC 60204-1]
EN 61800-5-1
[IEC 61800-5-1]
EMC Directive
2014/30/EU Declaration of Conformity
(If all installation instructions concerning
cable selection, cabling and EMC filters or
dedicated transformer are followed.)
EN 61800-3
[IEC 61800-3]
in accordance with 3ADW000032
Effect of the site elevation above sea level on the converter’s load capacity
Current reduction to % of nominal converter current
Effect of the ambient temperature on the converter‘s load capacity
Current reduction to % of nominal converter current
Ambient
temperature
Site elevation in m above M.S.L.
1000 m 2000 m 3000 m 4000 m
30°C
100 % 100 % 90 % 80 %
35°C
100 % 95 % 85 % 75 %
40°C
100 % 90 % 80 %
45°C
95 % 85 %
50°C
90 % 80 %
55°C
85 %
50
60
70
80
90
100
1000 2000 3000 4000 5000
m
30
70
80
90
100
110
35 40 45 50
DZ_LIN_017_current-reduction_a.ai
55°C