5.5. Updating revolution counters
General
This section details how to perform a rough calibration of each robot axis, i.e. updating the 
revolution counter value for each axis, using the pendant.
Step 1 - Manually running the robot to the calibration position 
This procedure details the first step when updating the revolution counter; manually running 
the robot to the calibration position. 
Step 2 - Storing the revolution counter setting with the TPU 
This section details the second step when updating the revolution counter; storing the 
revolution counter setting with the TPU (RobotWare 4.0). 
Action  Note 
1. Select axis-by-axis motion mode.   
2. Jog the robot to place the calibration marks  
within the tolerance zone.
IRB 140, 1400, 2400, 4400, 6600ID/
6650ID: Axes 5 and 6 must be positioned 
together!
Shown in section Calibration scales and 
correct axis position on page 238.
3. When all axes are positioned, store the 
revolution counter settings.
Detailed in section:
Step 2 - Storing the revolution counter 
setting with the TPU on page 241 
(RobotWare 4.0).
Step 2 - Storing the revolution counter 
setting with the FlexPendant on page 243 
(RobotWare 5.0).
  Action  Note
1. Press the button "Miscellaneous" then ENTER to select the service 
window. 
xx0100000194
Continues on next page